Controlink Systems LLC

Questions? Call us!

(812) 637-6800

(800) 838-3479

Questions? Call us!

(812) 637-6800(800)

838-3479

Controlink Systems LLC

QUICK

SERVE

WATCH and LEARN

How to get started with Quick Serve™

“The QUICK Serve DNC software continues to serve us well!"

Steve A./ Ametek, Inc.

GET STARTED!

Get Started in Quick Serve
Get Started in Quick Serve

QUICK Serve

QUICK START GUIDE

STEP #1

INTRODUCTION TO QUICK SERVE

We think setting up your software should be easy. You can watch the quick video above to learn how to install QUICK Serve, or... provided below are step by step instructions on how to get up and running.

CONFIGURE

Configuring your first CNC Machine

  • Run Machine Link™ QUICK Serve'

  • Click [CONFIGURE] and then select [Table], [Insert Row] from the top menu bar

  • Press [CONFIGURE] and enter the name of your machine

  • Enter configuration information for the machine (COM port, baud rate, data bits, stop bits, parity, etc.)

  • If you are unsure of the machine settings, start with the default values by clicking [DEFAULTS]

  • Check-mark [Active in Scan List]

  • Click [ACCEPT] and then [SAVE]

Pro Tip: Machine Link™ QUICK Serve has built-in help - turn it on by clicking [Help], [Show Context Help] from the top menu bar.

RECEIVING FILES

Manually receiving from your first CNC Machine

Important: It is recommended to successfully manually receive a file from the CNC machine tool before attempting to send a file to the CNC machine. Receiving a file will validate that the CNC machine's COM port and the computer's COM port are both operational and that the cable is, for the most part, configured correctly.

  • Select [File], [Receive from CNC] from the top menu bar

  • Select the machine tool name you entered from the [Configured Machine Controls] list

  • Click [RECEIVE] and then punch/output the file from the machine tool control

  • Machine Link™ QUICK Serve will continue to wait until activity is seen on the COM port. When data is seen, Machine Link™ QUICK Serve will begin to flash, indicating that data is being received

  • After successfully receiving a file, press [SAVE] and then [EXIT]

SENDING FILES

Manually sending to your first CNC Machine

  • Once you have successfully received a file with Machine Link™ QUICK Serve, prepare the CNC machine tool control to receive a file

  • Select [File], [Send to CNC] from the top menu bar

  • Select the machine tool name you entered from the [Configured Machine Controls] list

  • Click [SELECT FILE] and select the previously-saved CNC program file

  • Click [SEND] ‐ the selected file will be transferred to the CNC machine

TROUBLESHOOTING

  • If Machine Link™ QUICK Serve does not flash, insert a null modem adaptor and resend the file

  • If Machine Link™ QUICK Serve still does not flash, perform a COM Port/Cable Test

  • If Machine Link™ QUICK Serve flashes, but the file is garbled, adjust the communication parameters

Still having problems? Give us a call at (800) 838-3479. We are here and happy to help!

Need more info? Watch all of our training videos below!

OR download our user manual HERE.

Why choose QUICK SERVE?

SIMPLE AND POWERFUL.

Improve Productivity

IMPROVE PRODUCTIVITY

Boost your productivity by allowing machinists to request files remotely, never having to leave their CNC machine.

Increase Quality

INCREASE QUALITY

CNC programs can often be improved, so if you edit your CNC program while at the machine, you can send it off for internal approval to become the starting point of your next download.

Maximize CNC Equipment Uilization

MAXIMIZE CNC EQUIPMENT UTILIZATION

Requesting files remotely helps to keep your setup time low and your machine utilization high.

Manage CNC File Revisions

MANAGE CNC FILE REVISIONS

Put engineering in full control to quickly review and manage shop-floor changes to help improve overall shop efficiency and safety.

Work Safer And Smarter

WORK SAFER AND SMARTER

Improve safety by keeping machine-side edits to a minimum and using GCODE that is ready to run.

Customize The Code

CUSTOMIZE THE CODE

We are willing to customize the software for your shop to streamline installation and deliver even greater impact.

TUTORIALS

WATCH ALL OF OUR TRAINING VIDEOS

Controlink Systems LLC

REGISTER YOUR

COPY AND UNLOCK
YOUR LICENSE OF QUICK SERVE!

Quick Serve Replacement Plan

Quick Serve Protection Plan
Quick ServeReplacement Plan

Replacement Plan

Comes standard and provides peace of mind when computers fail.

Quick Serve Computer Failures

Computer Failures

If your computer fails during the first 2 years and you reinstall the software, you will receive another registration code free of charge (maximum of 2).

Quick Serve 50% Off Replacements

50% Off Replacements

If your computer fails after 2 years, you will receive 50% off your replacement order for being a loyal customer.

Need a quote for professional installation? Call or email us today!

Controlink Systems LLC

Contact

800-838-3479

Email Us

Address

24545 Lela Dr, Lawrenceburg,

IN 47025, United States